30-60KW Commercial and Industrial Inverter | Three-phase 3-6 MPPT

The commercial and industrial 30-60kW inverter is for medium to large-scale commercial and industrial rooftop solar systems. The unit ensures maximum energy output because of its very high efficiency conversion rate at 98.6%. It has 3-6 MPPT, allowing the system to handle multiple rooftop orientations at once, boosting overall efficiency. With a unit weighing just 55 kg, it is optimized, keeping in mind ease of installation and operation. The maximum DC input voltage of 1100V and the wide MPPT operating voltage range enable longer operating hours in order to maximize energy yield and ensure long-term profitability.

Get a Quote Now

TAG: High Power Inverter (> 10kW), MPPT Inverter, Three-phase Inverter

What are the advantages of 30-60KW Commercial and Industrial Inverters?

  • 1.5x DC Overload Capacity: Allows for higher energy generation to ensure greater returns.
  • Zero Voltage Ride Through (ZVRT): Enhances grid stability in case of power fluctuations.
  • Fuse-free Design: Increases reliability, reduces maintenance costs.
  • AFCI 3.0 Technology: Arc fault detection powered by AI has less than 0.5 seconds of response time to guarantee top safety due to its strong detection and shutdown upon recognition of an electrical arc. Ensuring your safety at most demanding high-power installations-up to 200 meters of its detection range.
  • Maximum Efficiency: Designed to be capable of 10% optimized maximum AC output, this inverter makes sure energy efficiency remains higher even during peak loads.

What are the characteristics of 30-60KW Three-phase 3-6 MPPT Inverters?

  • PID Repair Function: This function operates a DC bias voltage between PV negative and ground during non-operating hours. It will renew the module performance and prevent power degradation caused by PID.
  • Repair Efficiency: This repair efficiency could go up to 99% to ensure the solar module is problem-free in continuous operation.
  • More Safety Features:
    • ARC Detection DC: Arcing in the DC circuit can be detected to further increase the safety of the systems.
      AC/DC Surge Protection-can protect the system from AC/DC voltage surges.
    • System Benefits: These attributes enhance safety and durability for the system, therefore offering reliability in performance and assurance of safety during extreme conditions.

What are the technical specifications of the 30-60KW Three-phase 3-6 MPPT Inverters?

Parameter 30kw 36kw 40kw 50kw 60kw
Maximum Input Voltage (V) 1,100 1,100 1,100 1,100 1,100
MPPT Voltage Range (V) 200~950 200~950 200~950 200~950 200~950
Start Voltage (V) 160 180 180 180 180
Rated Input Voltage (V) 600 600 600 600 600
Maximum Input Current per MPPT (A) 30 30 30 30 30
Maximum Short-Circuit Current per MPPT (A) 37.5 37.5 37.5 37.5 37.5
Number of MPPTs 3 3 4 5 6
Modules per MPPT String 2 2 2 2 2
Rated Output Active Power (W) 30,000 36,000 40,000 50,000 60,000
Maximum Output Active Power (W) 33,000 37,800 44,000 55,000 66,000
Maximum Output Apparent Power (VA) 33,000 37,800 44,000 55,000 66,000
Rated Output Voltage (V) 380, 3L/N/PE or 3L/PE 380, 3L/N/PE or 3L/PE 380, 3L/N/PE or 3L/PE 380, 3L/N/PE or 3L/PE 380, 3L/N/PE or 3L/PE
Output Voltage Frequency (Hz) 50 50 50 50 50
Maximum Output Current (A) 48 54.5 63.8 80 96
Power Factor -1(0.8 leading..0.8 lagging adjustable) -1(0.8 leading..0.8 lagging adjustable) -1(0.8 leading..0.8 lagging adjustable) -1(0.8 leading..0.8 lagging adjustable) -1(0.8 leading..0.8 lagging adjustable)
Total Harmonic Distortion <3% <3% <3% <3% <3%
Maximum Efficiency 98.8% 98.8% 98.6% 98.6% 98.6%
Chinese Efficiency 98.5% 98.5% 98.1% 98.1% 98.1%
DC Current Monitoring Integrated Integrated Integrated Integrated Integrated
Residual Current Monitoring Integrated Integrated Integrated Integrated Integrated
Anti-Islanding Protection Integrated Integrated Integrated Integrated Integrated
Input Reverse Protection Integrated Integrated Integrated Integrated Integrated
DC Arc Fault Protection Three levels (Two levels optional) Three levels (Two levels optional) Three levels (Two levels optional) Two levels (One level optional) Two levels (One level optional)
AC Leakage Protection Three levels (Two levels optional) Three levels (Two levels optional) Three levels (Two levels optional) Two levels (One level optional) Two levels (One level optional)
AC Overcurrent Protection Integrated Integrated Integrated Integrated Integrated
AC Short-Circuit Protection Integrated Integrated Integrated Integrated Integrated
AC Overvoltage Protection Integrated Integrated Integrated Integrated Integrated
Working Temperature Range (°C) -30 ~ 60 -30 ~ 60 -30 ~ 60 -30 ~ 60 -30 ~ 60
Relative Humidity 0~100% 0~100% 0~100% 0~100% 0~100%
Maximum Working Altitude (m) 3,000 3,000 4,000 4,000 4,000
Cooling Method Liquid cooling Smart Air Cooling Liquid cooling Smart Air Cooling Smart Air Cooling
Human-Machine Interaction LCD, LED LCD, LED or LED, APP LCD, LED LCD, LED, APP LCD, LED, APP
Communication Method RS485 or WiFi or 4G or PLC RS485 or WiFi or 4G or PLC RS485 or WiFi or 4G or PLC RS485 or WiFi or 4G or PLC RS485 or WiFi or 4G or PLC
Weight (Kg) 40.0 40.0 42.0 55.0 55.0
Dimensions (W x H x D mm) 480×590×200 480×590×200 480×590×200 520×660×220 520×660×220
Protection Level IP65 IP65 IP65 IP65 IP65
Night Self-Consumption (W) 1 1 1 1 1
Topology Structure Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated
Grid Standard NB/T32004 NB/T32004 NB/T32004 NB/T32004 NB/T32004
Safety Standard NB/T32004 NB/T32004 NB/T32004 NB/T32004 NB/T32004
EMC Standard NB/T32004 NB/T32004 NB/T32004 NB/T32004 NB/T32004